Concrete cosmetic

Created by   Synfola®


Formwork types according to SIA
118/262



Type 1

Type 1 Usual concrete surface without special optical surface requirements



Type 1 Usual concrete surface without special optical surface requirements

- With arbitrary area structure
- Without post-processing of ridges and high spots

Type 2

Type 2 Concrete area with uniform surface structure




Type 2 Concrete area with uniform surface structure

- Plank or panel size not defined
- With post-processing of ridges and high spots






Type 3

Type 3 Exposed concrete surface with plank structure.

Type 3 Exposed concrete surface with plank structure. Visible remaining surfaces with the following requirements


- Unified surface structure without high spots, ridges
  and porous areas.
- Pores (shrink holes) caused by air pockets are
  allowed in moderate number
- Colouring as unified as possible
- Constant plank size, plank joints not defined
- Unified plank direction and parallel to larger dimension
  of the formwork area
- Smooth formwork planks


Type 4

Type 4 Exposed concrete surface with panel structure.

Type 4 Exposed concrete surface with panel structure. Visible remaining surfaces with the following requirements

- Unified surface structure without high spots, ridges
  and porous areas.
- Pores (shrink holes) caused by air pockets are
  allowed in moderate number
- Colouring as unified as possible
- Constant panel size, panel joints not defined
- Unified panel direction and parallel to larger dimension
  of the formwork area

Type 5

Type 5 Exposed concrete with precise description of the planner




Type 5 Exposed concrete with precise description of the planner. Uniformly closed surface


Drilling holes, concrete remainders, swelling of sintered layer, repair spots, damages caused by vibration needle etc. are not permitted. Use of bakelised plywood panels.